HV Switchgear Enhanced Ratings

Giving network operators a defensible basis to run high-voltage switchgear harder, for longer, when the network needs it.

No published standard tells an operator how far high-voltage switchgear can safely be pushed above its normal rating, or for how long. Threepwood built the guidance and the calculator that provide the justification.

The challenge

No guidance is currently available to temporarily operate high-voltage (HV) switchgear above its normal load current rating. When demand peaks, or a fault pushes load onto neighbouring circuits, operators have no recognised basis for justifying a short-term overload.

No current published national or international standard addresses the problem, so decisions are made conservatively, and flexibility that the network could safely use is left on the table.

There is opportunity to provide guidance and tools that can assist network operators to justify temporary short-term overloading of certain switchgear.
The opportunity Threepwood set out to address

Our approach

Threepwood developed a guidance document, supported by a calculator tool, that lets operators justify temporary overloading situations. Rather than judging switchgear against a single steady-state rating, the method models how equipment temperature responds to a defined loading period.

A short-term overload can then be assessed against the equipment’s thermal limit and its time constant, so the loading a circuit can carry over a fixed window is understood, not guessed.

Schematic: modelled equipment temperature during a short-term loading window, assessed against its thermal limit rather than its steady-state rating.

The outcome

The results

01

Keeps supplies on

Provides short-term flexibility to maintain supplies when the network is under strain.

02

Rides through faults

Allows supplies to be maintained following fault outages, where the network may be temporarily overloaded.

03

Defers capital cost

May assist in deferring asset replacement and the associated costs.

Facing a similar challenge?

Put the same rigour to work on your network

From switchgear ratings to substation design and asset management, we help network operators justify decisions and defer cost. Tell us about your project.


More case studies

Threepwood Consulting HV safe systems of work webinar
Electrical Safety

Internal Arc Integrity for Cable Transits

An internal arc fault turns a switchgear enclosure into a pressure vessel in milliseconds. Threepwood’s white paper assessed how a Roxtec cable transit system maintains that enclosure’s tested arc classification, giving operators an evidence base to specify it with confidence.

Electrical safety engineering by Threepwood Consulting
Electrical Asset Management

Overhead Line Enhanced Ratings

Static seasonal ratings treat every hour as the worst hour. Threepwood built the method and the tooling to rate overhead lines against the conditions they are actually experiencing, releasing capacity that is already there, safely within thermal and clearance limits.

G5 Harmonic Assessment
Networks Compliance

ESB Networks LCT Register Compliance

Heat pumps, EV chargers and inverter-connected generation must be registered with ESB Networks before they can be connected. Threepwood acts as the LCT Compliance Agency, taking manufacturers and installers through registration.